We can bring you the solution: HPLC apparatuses, columns and applicative help by our trained experts.
We are representatives of Phenomenex, a renowned American manufacturer. Phenomenex is known for their first-rate columns for which they constantly develop newer and better stationary phases.
Used for fingerprinting and routine analyses of quality control.
Low-polar column for a wide variety of applications
An alternative for any kind of columns with a 100 % dimethylpolysiloxane phase
Various lengths of columns (m): 10, 15, 30, 50, 60, 100
Various inner diameters (mm): 0.25, 0.32, 0.53
Temperature resistance: - 60 °C – 360/370 °C (thicker films (≥1.0 µm df) have a resistance up to 340/360 °C (Isothermal/TPGC)).
Used for active components, such as drugs, pesticides, acids and bases.
Very low bleeding, especially suitable for GC/MS
Phase: 100% dimethylpolysiloxane high temperature
Identical selectivity as with the classic ZB-1 phase
USP phase: G2
Temperature resistance: - 60 °C – 360/370 °C (Isothermal/TPGC)
Various lengths of columns (m): 10, 12, 20, 25, 30, 60
Various inner diameters (mm): 0.10, 0.20, 0.25, 0.32
First non-metal 100 % Dimethylpolysiloxane phase, stable at up to 430 °C, individually tested for low bleeding, MS certified and equipped with ESC technology.
Rugged, high temperature stable (430 °C), polyimide-coated fused silica phase
Robust column performance for high temperature bake outs
True boiling point separation for hydrocarbon distillation methods
Recommended for chemists struggling with high boilers, contaminants, or carry-overs
Temperature resistance: - 60 °C – 400/430 °C (Isothermal/TPGC)
Various lengths of columns (m): 15, 20, 30
Various inner diameters (mm): 0.18, 0.25, 0.32, 0.53
Versatile column recommended for a wide range of applications
Great column for unknown samples
Resilient to dirty samples – long column life
An alternative for any other 5 %-phenyl-95%- dimethylpolysiloxane phase
Low bleeding (MS certified) – especially suitable for extremely sensitive work with GC/MS
Various lengths of columns (m): 15, 20, 30, 60
Various inner diameters (mm): 0.25, 0.32, 0.53
Extremely inert for active components, such as drugs and pesticides
Temperature resistance: - 60 °C – 360/370 °C (thicker films (≥1.0 µm df) have a resistance up to 340/360 °C (Isothermal/TPGC)).
Most popular starting column for method developers (525, 610, 625, 8100 and 8270)
Arylene Matrix Technology (AMT) provides a highly stable arylene phase for enhanced resolution of PAHs and multi-ring aromatic compounds
Low bleed (MS certified) especially suited to high sensitivity work using GC/MS
Conditioned in 35 minutes
Enhanced resolution of PAHs and other multi-aromatics
USP phase: G27
Temperature resistance: - 60 °C – 325/350 °C (Isothermal/TPGC)
Various lengths of columns (m): 10, 15, 20, 30, 60
Various inner diameters (mm): 0.10, 0.25, 0.32
Highly inert for improved peak shape of acidic/basic compounds, drugs of abuse, and pesticides
MS certified low bleed levels provide maximum sensitivity
Traditional bonding chemistry provides the same selectivity as other 5% phenyl columns
ESC (Engineered Self Cross-linking) technology improves phase stability and temperature resistance
Same selectivity as with the ZB-5 column
Temperature resistance: - 60 °C – 360/370 °C (thicker films (≥1.0 µm df) have a resistance up to 340/360 °C (Isothermal/TPGC))
Various lengths of columns (m): 10, 15, 20, 30, 60
Various inner diameters (mm): 0.25, 0.32
First non-metal 100 % Dimethylpolysiloxane phase, stable at up to 430 °C, individually tested for low bleeding, MS certified.
Rugged, high temperature stable (430 °C), polyimide-coated fused silica phase
Robust column performance for high temperature bake outs
Temperature resistance: - 60 °C – 400/430 °C (Isothermal/TPGC)
Various lengths of columns (m): 15, 20, 30
Various inner diameters (mm): 0.18, 0.25, 0.32, 0.53*
* 0.53 mm ID column is temperature resistant only up to 400 °C.
First non-metal, enhanced durability 35% phenyl phase with 400 °C temperature stability
Great for high molecular weight compounds
Robust column performance for high temperature bake outs
MC certified and equipped with ESC technology
Temperature resistance: 40 °C – 400 °C (Isothermal/TPGC)
Various lengths of columns (m): 15, 30
Various inner diameters (mm): 0.25, 0.32
Intermediate polarity column for high molecular weight analysis
Inert to minimize analyte adsorption, improve efficiency, and reproducibility
More rugged (longer column life) than other polar phases
Excellent for trace analysis with bleed-sensitive detectors (MS, FID, ECD, NPD)
Temperature resistance: 40 °C – 340/360 °C (Isothermal/TPGC)
UPS phase: G42
Differentiates between components that overlap at phases ZB-1 and ZB-5.
High polarity column capable of high temperature bake out to remove contaminants
Inert to minimize analyte adsorption, improve efficiency, and reproducibility
More rugged (longer column life) than other polar phases
Great for toxicology and environmental compounds
The appropriate choice for EPA methods 508, 608, 8081, 8141, 8151
USP phase: G3
An alternative for any 50 %-phenyl-50 % dimethylpolysiloxane phase
Increased temperature limit speeds run times and re-equilibration
Popular choice for residual solvent testing (USP Monograph <467>)
Widely used to separate volatile organic flavour and fragrance additives and residual solvents in industrial or pharmaceutical products (OVIs)
Equivalent to USP phase G43
Formulated for low bleeding
Available in “Fast GC” version
The appropriate choice for EPA methods 501.3, 502.2, 503.1, 524.2, 601, 602, 8010, 8015, 8020, 8021, 8240, 8260
Temperature resistance: -20 °C – 260 °C
Specially engineered column set specifically designed for pesticide screening and confirmation by GC/ECD, GC/NPD, and GC/MS
Resolve common pesticide isomers with optimized selectivity for food and environmental samples
Improved inertness for decreased breakdown of sensitive pesticides such as DDT
Exceed EPA Method 8081 specifications for dual column confirmation when used with ZB-MultiResidue-2
Alternate selectivity for mid-polarity analyses
Fast run and re-equilibration times for enhanced sample throughput and productivity
Provides alternate selectivity to phenyl phases with similar polarity
An alternative for any 14 %- cyanopropylphenyl-86 % - dimethylpolysiloxane phase
Specially tested to ensure response of DDT, Endrin, Endrin Aldehyde, and Endrin Ketone
Guaranteed column for pesticide analysis
EPA Method 8081 Certified
USP phase: G46
Unique low polarity si-arylene column for MS detectors
Provides alternative selectivity to standard 5-type phases
Often used for confirmation of pesticide, PCB, or other environmental samples
Good tool for sample screening to identify unknown contaminants
Non-metal si-arylene low bleed phase stable to 400 ˚C
Provides alternate selectivity to 5% phenyl phases
Often used for confirmation of pesticides, PCB, or other environmental samples
Robust column performance for high temperature bake outs
Bonded, solvent-rinse-able phase excellent for separating polar complex mixtures
GC/MS Certified low bleed levels
Low activity for amines
Excellent separations of polar complex mixtures; widely used for profiling and "fingerprinting"
100% aqueous stable, excellent for aqueous samples; bonded and solvent rinse-able
Extremely inert for acidic compounds
Enhanced selectivity for low boiling solvents; high retention of alcohols and chlorinated solvents
Increased efficiency at 20 °C
USP phase: G16
Popular choice for food industry method development
High polarity column with excellent thermal and chemical stability
Improve peak shape for underivatized acids, organic acids, free fatty acids, and alcohols
Bonded, solvent rinse-able nitroterephthalic acid phase
Specially deactivated to improve inertness and quantitation for drug compounds
Quickly and accurately analyze drug of abuse with great peak shape
Improve resolution of target analytes from matrix interferences
Run amphetamines in under 6 minutes and opiates in under 5 minutes
Proprietary column set specially designed for accurate blood alcohol analysis — enhance resolution of ethanol and acetone peaks
Resolves t-butanol and n-propanol for greater selection of internal standards
Fast run time with baseline resolution of key components in just 2 minutes
Achieve dual column confirmation - get two elution order changes with ZB-BAC-2