Phenomenex

HPLC Columns

Are you looking for a comprehensive solution to your chromatography problems?

We can bring you the solution: HPLC apparatuses, columns and applicative help by our trained experts.

We are representatives of Phenomenex, a renowned American manufacturer. Phenomenex is known for their first-rate columns for which they constantly develop newer and better stationary phases.

New Luna Omega HPLC/UHPLC columns with selections we have not yet offered

 

Excellent first choice for chromatographers who are just starting method development or attempting to improve upon existing chromatographic results with other C18s. With its higher performance potential, excellent retention profile, and greater inertness, the Luna Omega C18 was designed to be the new all-purpose UHPLC solution for industries all over the world.

 

 

 

 

 

A novel UHPLC stationary phase capable of providing a unique selectivity within a wide elution window and increased retention for both polar and non-polar analytes. The all-purpose C18 ligand provides hydrophobic interactions while a polar modified particle surface provides enhanced polar retention and also aqueous stability. These attributes make the Luna Omega Polar C18 an excellent choice for balanced retention of polar and hydrophobic compounds as well as to solely enhance retention of highly polar compounds.

 

 

 

 

A unique mixed-mode stationary phase that provides incredibly useful polar and non-polar retention. The surface of the PS C18 contains a positive charge which aids in the retention of acidic compounds through ionic interactions, while the C18 ligand promotes general reversed phase retention. This mixed-mode selectivity allows for greater separation between compounds with varying functional groups as well as better peak shape for basic analytes.

 

 

 

 

 

The NEW Luna Omega SUGAR breaks ground as it combines the performance benefits of thermally modified fully porous particles with a novel HILIC stationary phase that excels at polar compound retention and selectivity.

  • Improved carbohydrate retention and separation with novel HILIC selectivity
  • Enhanced lifetime with highly robust and efficient thermally modified fully porous particle
  • QC tested for sugars to ensure reliable quality

 

 

Click to view PDF brochure

 


 

 

Revolutionary HPLC columns KINETEX® enable UHPLC on regular LC systems

The benefits of using the KINETEX® columns:

  • Reaching the effect of sub-2  µm particles within the HPLC restrictions for back pressure

  • Exchange your 3 µm and 5 µm columns for 2-3 times better effectiveness

  • Reduced quantity of solvents due to faster analyses

  • Easier transfer of methods to any LC system

  • Phases: EVO-C18, C18, XB-C18, Polar C18, PS C18, C8, F5, Biphenyl, HILIC, Phenyl-hexyl in PAH 

     


Rezultat iskanja slik za BIOZEN hplc

bioZenTM HPLC and UHPLC biochromatographic columns for protein and peptide analysis

Advantages of use bioZenTM columns:

  • Inert titanium hausing

  • HPLC and UHPLC columns

  • Particle size: 1,6um, 1,7um, 1,8um, 2,6um, 3,6um, 6um

  • Reverse faze chromatography, SEC, HILIC in IEX

  • Fazes: Intact XB-C8, Intact C4, SEC-2, SEC-3, Peptide PS-C18, Peptide XB-C18, Glycan, WCX

 


GEMINI® - universal columns for an extremely wide range of usage and shelf life

We offer:

  • Phases:  C18, NX (durable C18 phase), C6-Phenyl,

  • Special patented structure of the stationary phase enables pH stability in range from 1 to 12, and high mechanical strength.

 


Highly pure silica gel (99.999 %) and smooth particle surface assure robustness and long shelf life of Luna® HPLC Columns

We offer phases:

Silica, C5, C8, C18, Phenyl-hexyl, CN, NH2, SCX, HILIC, PFP.

 


Rid yourselves of problematic compounds during analysis – choose Synergi HPLC Columns!

Synergi HPLC Columns: Synergi MAX-RP, Polar-RR, Hydro-RP and Fusion-RP are intended for the use in special cases when regular columns do not provide the results necessary.  The most common problems occur when we try to analyse alkaline compounds and come across tailing, have very polar aromatic analytes, wish to work at 100 % water conditions or have a whole mix of polar and nonpolar analytes in our samples. Each one out of the four phases of Synergi columns can help you solve these problems:  MAX-RP, Polar-RR, Hydro-RP and Fusion-RP.

Choose the appropriate Synergi HPLC Columns for your analysis:

• Max-RP,

• Polar-RR,

• Hydro-RP and

• Fusion-RP.

 


Optimise chiral separations and purification of chiral compounds with LUX Columns!

LUX chiral columns are based on polysaccharides. Cellulose and amylose chiral selectors offer a wide range of selectivity that allows you to effectively search for a chiral separation in a reversed-phase mode, polar organic mode, normal phase mode or SFC.

Available chiral LUX phases:

Lux Amylose-1

Amylose tris(3,5-dimethylphenylcarbamate)

Guaranteed alternative for: CHIRALPAK® AD®, AD-H®, AD-3, AD-RH, and AD-3R

Lux Amylose-2

Amylose tris(5-chloro-2-methylphenylcarbamate)

Guaranteed alternative for: CHIRALPAK® AY®, AY-H®, AY-3, AY-RH, and AY-3R

Lux Cellulose-1

Cellulose tris(3,5-dimethylphenylcarbamate)

Guaranteed alternative for: CHIRALCEL® OD®, OD-H®, OD-3, OD-RH, and OD-3R

Lux Cellulose-2

Cellulose tris(3-chloro-4-methylphenylcarbamate)

Guaranteed alternative for: CHIRALCEL OZ, OZ-H®, OZ-3, OZ-RH, and OZ-3R

Lux Cellulose-3

Cellulose tris(4-methylbenzoate)

Guaranteed alternative for: CHIRALCEL OJ®, OJ-H®, OJ-3, OJ-RH, and OJ-3R

Lux Cellulose-4

Cellulose tris(4-chloro-3-methylphenylcarbamate)

Guaranteed alternative for: CHIRALCEL OX-H®, OX-3, OX-RH, and OX-3R

 


Optimal solution for characterization and purification of proteins and peptides!

We offer:

  • Jupiter® 300 (phases C4, C5 and C18) and

  • Jupiter® Proteo.

 


Monolithic HPLC Columns Onyx

  • Shortens the duration of analysis by 50 %,

  • highly effective with a low back pressure,

  • you can choose between C18, C8 and Silica phases,

  • available also in 2 mm ID format.

 


Do you need advice
from an expert
Fill out the question
Fill out the name
Fill out the contact